84 DS882F1
CS42L73
6.6 Power Control 3 and Thermal Overload Threshold Control (Address 08h)
6.6.1 Thermal Overload Threshold Settings
Configures the threshold temperature level for the Thermal Overload Interrupt Status bit.
6.6.2 Power Down Thermal Sense
Configures the power state of Thermal Sense circuit.
6.6.3 Power Down Speakerphone Line Output
Configures the Speakerphone Line Output Driver power state. If the Speakerphone Line Output Driver or
Ear Speaker Driver is powered up, the DAC that drives them is powered up; otherwise, it is powered down.
6.6.4 Power Down Ear Speaker
Configures the Ear Speaker Driver power state. If the Speakerphone Line Output Driver or Ear Speaker
Driver is powered up, the DAC that drives them is powered up; otherwise, it is powered down.
6.6.5 Power Down Speakerphone
Configures the power state of the Speakerphone DAC and Driver.
76543210
THMOVLD_
THLD1
THMOVLD_
THLD0
PDN_THMS PDN_SPKLO PDN_EAR PDN_SPK PDN_LO PDN_HP
THMOVLD_THLD[1:0] Nominal Threshold Level (
°C)
00 Refer to table “Thermal Overload Detect Characteristics” on page 25
01 to 11
Application: “Thermal Overload Notification” on page 42
PDN_THMS Thermal Sense Status
0 Powered Up
1 Powered Down
Application: “Thermal Overload Notification” on page 42
PDN_SPKLO Speakerphone Line Output Driver Status
0 Powered Up
1 Powered Down
PDN_EAR Ear Speaker Driver Status
0 Powered Up
1 Powered Down
PDN_SPK Speakerphone DAC and Driver Status
0 Powered Up
1 Powered Down