SYNC1
Function: Part of the serial port re-initialization sequence.
SYNC0
Function: End of the serial port re-initialization sequence.
NULL
Function: This command is used to clear a port flag and keep the converter in the continuous conversion
mode.
D7(MSB) D6 D5 D4 D3 D2 D1 D0
11111111
D7(MSB) D6 D5 D4 D3 D2 D1 D0
11111110
D7(MSB) D6 D5 D4 D3 D2 D1 D0
00000000