Cirrus-logic AN365 Manuale Utente Pagina 12

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 14
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 11
AN365
12 AN365REV1
4.3.2 Reactive Energy Load Performance
Figure 11. Reactive Energy Load Performance
Power Factor Load Current (A) Current Dynamic Range (x:1) Error
sin = 1
120 1 -0.02%
60 2 -0.02%
12 10 -0.03%
1.2 100 -0.03%
0.24 500 0.03%
0.12 1000 0.01%
0.06 2000 0.02%
0.036 3333 0.09%
0.03 4000 0.08%
Lagging = 0.5
120 1 0.19%
60 2 0.19%
12 10 0.19%
1.2 100 0.17%
0.24 500 0.20%
0.12 1000 0.26%
0.06 2000 0.23%
Leading = 0.5
120 1 -0.23%
60 2 -0.22%
12 10 -0.24%
1.2 100 -0.24%
0.24 500 -0.2%
0.12 1000 -0.16%
0.06 2000 -0.17%
Table 10. Reactive Energy Load Performance
-1
-0.5
0
0.5
1
0.01 0.1 1 10 100
Percentage Error (%)
Load Current (A)
sin = 1 Lagging sin = 0.5 Leading sin = 0.5