CS5378
DS639F3 17
SWITCHING CHARACTERISTICS
Test Bit Stream (TBS)
5. TBSDATA can be delayed from 0 to 63 full bit periods. The timing diagram shows no TBSDATA delay.
Parameter Symbol Min Typ Max Unit
TBS Data Output Timing
TBS Data Bit Rate - 256 - kbps
TBS Data Rising to MCLK Rising Setup Time t
1
60 - - ns
MCLK Rising to TBS Data Falling Hold Time (Note 5) t
2
60 - - ns
Figure 8. TBS Output Data Timing
TBSDATA
MCLK
t
2
t
1
Note: Example timing shown for a 256 kHz output rate and no programmable delays.