RECOMMENDED OPERATING SPECIFICATIONS (AGND = 0V; all voltages with respect
to AGND.)
ABSOLUTE MAXIMUM RATINGS (AGND = 0 V; all voltages with respect to ground.)
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation is
not guaranteed at these extremes.
Parameters Symbol Min Typ Max Units
DC Power Supply VA
VL
4.75
1.8
5.0
-
5.25
VA
V
V
Parameters Symbol Min Max Units
DC Power Supply VA
VL
-0.3
-0.3
6.0
VA
V
V
Input Current, Any Pin Except Supplies I
in
10mA
Digital Input Voltage V
IND
-0.3 VL+0.4 V
Ambient Operating Temperature (power applied) T
A
-55 125 °C
Storage Temperature T
stg
-65 150 °C