Cirrus-logic CS5461A Manuale Utente Pagina 25

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 44
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 24
CS5461A
DS661F3 25
5.14.6 Calibration
The CS5461A can perform system calibrations. Proper input signals must be applied to the current and voltage
channel before performing a designated calibration.
CAL[4:0]* Designates calibration to be performed
01001 = Current channel DC offset
01010 = Current channel DC gain
01101 = Current channel AC offset
01110 = Current channel AC gain
10001 = Voltage channel DC offset
10010 = Voltage channel DC gain
10101 = Voltage channel AC offset
10110 = Voltage channel AC gain
11001 = Current and Voltage channel DC offset
11010 = Current and Voltage channel DC gain
11101 = Current and Voltage channel AC offset
11110 = Current and Voltage channel AC gain
*Values for CAL[4:0] not specified should not be used.
B7 B6 B5 B4 B3 B2 B1 B0
1 1 0 CAL4 CAL3 CAL2 CAL1 CAL0